QTOF with Micros

Research-grade Q-TOF LCMS. Perform Critical Analysis with Confidence.

A product of Shimadzu’s engineering DNA, the Q-TOF LCMS-9030 enhances the most important features of Q-TOF instrumentation – mass accuracy, sensitivity and speed – to enable users to effortlessly conduct critical qualitative and quantitative analysis with genuine confidence and ease. Combine with the unmatched solvent delivery of our UHPLC pumps and the rapid cycle times of our sample injectors to achieve unmatched reproducible, high-throughput analysis.

Key benefits include:


Reproducible Results
The LCMS-9030 Q-TOF delivers outstanding mass accuracy over a wide mass range, enabling users to consistently produce accurate identification results. In addition, the LCMS-9030 requires infrequent calibration, making it easy to achieve high mass accuracy over long periods.

High Sensitivity Detection
High efficiency ion guides, quadrupole, and collision cell enable high sensitivity for the detection of trace level compounds. And, due to its robust platform, the LCMS-9030 achieves reproducible quantitative analysis over longer periods of time.

Ultrafast Performance
The LCMS-9030 incorporates the patented ultrafast technologies used in Shimadzu LC-MS/MS platforms to deliver outstanding speed. Innovative TOF architecture enables precise, ultra-fast pulsing of ions into the flight tube and ideal reflection back to the detector. The result is high-speed data acquisition compatible with the high-throughput laboratory.

Compatible with Microflow Analysis
Designed for optimal sensitivity and ease of use, the Micro-ESI 9030 interface brings microflow analysis to the Q-TOF LCMS-9030 using the Nexera Mikros. It detects target components with much higher sensitivity compared to analytical systems, features shorter analysis times and is more durable than nano flowrate compatible LCMS systems.

Core Ion Beam Technologies


The Q-TOF LCMS-9030 builds on proven LC-MS/MS technology and combines it with powerful TOF architecture to create a platform that transforms high mass accuracy workflows. These technologies include:

UFaccumulationTM
Ion accumulation in the collision cell, synchronized perfectly with short cycles of data acquisition, maximizes sensitivity.

UFgratingTM
Made with substantial mechanical strength, this grating is able to withstand the high voltages needed for ultrafast ion pulsing.

Funnel MCP
Lossless microchannel plate design maximizes sensitivity.

UF-FlightTubeTM
The temperature-controlled UF-FlightTube requires less frequent calibration, enabling you to run more samples.

iRefTOFTM
Meticulously manufactured plate electrodes are stacked to create a reflectron that delivers a high resolution flight path with highly stable mass accuracy.